The N180 adjust amperage according to gpm demand place on heater. Does the n180 have a demand feature of any kind for the amount of water flow needed? Easy access.Ģ08 current w/ 2 40 amp breakers in Tampa, Florida do you think the N180 will handle two baths.
![calentador de agua titan n-120 reparaciones calentador de agua titan n-120 reparaciones](https://gt.epaenlinea.com/pub/media/catalog/product/cache/3f8a07f91ed96197ac7613a4e8859f2d/8/f/8f218486-54a7-4718-b951-b7e2387c0a25.jpg)
Where fo wires land hows is electrical hooked upĭual line primary terminal junction/block w/ground located under heater casing.
#Calentador de agua titan n 120 reparaciones install
Hope this helps.ĭo I need the sediment filter if I am on city waterĭoes the unit come with complete install instructions This is a (2) line heater at 40 amps each (220 VAC). So the unit does not need a neutral? Both black and white go into the same breaker and it just uses the ground to protect it? Yes this heater will work perfect for your enviroment for the whole house with one bathroom. Would this unit work in cold environment for only supplying a single shower bathroom? I see warm or moderate climates mentioned. We live in a cold environment, NW Wyoming, on city water. To recap you will need 2 electrical circuits rate at 40 amp/ 220VAC each.ĭoes this type of heater can be used in Argentina?. You will need 2- double 40 amp breaker with number 8/2 AWG wire to install this unit properly. The disconnect(2) are installed right under the heater. The existing wires for your current heater will not work. In general am I going to have to run new wire from main box to power this or will the existing wires for the heater be sufficient. disconnect boxes take the place of changing out the breakers at the main box? I have a 40 gallon hotpoint that I need to replace. What's the distance between pipes connections?ĭo the a.c. If it was a one (1) line heater it would be wired with 1) 80 amp double pole and 4 gauge THHN wire.Īre the fittings 3/4 compression or 3/4 NPT?
![calentador de agua titan n-120 reparaciones calentador de agua titan n-120 reparaciones](http://calentadorestitan.com/images/modelos/electrico20lt-03.png)
Thats a total of 80 amp circuit divided by 2. The N180 is wired with 2) 40 amp double pole breakers and 8 gauge wire. You say that #8wire will work but #8 is not good for 75 amps Yes you can but unlike conventional tanks these heating elements are proprietary and very durable very hard for them to go out on you. Can you replace the heating elements if they ever go out?